Shockwave Javelin Peripheral

Lead the charge with our first-of-its-kind Forward Intravascular Lithotripsy (IVL) platform. It’s Shockwave peripheral IVL redefined to modify and cross calcified occlusive disease above and below the knee.

Product image of the Shockwave generator and Shockwave Javelin Peripheral IVL catheter
Product image of the Shockwave generator and Shockwave Javelin Peripheral IVL catheter

Shockwave Javelin Peripheral logo

Shockwave Javelin Peripheral: Crack & Cross Calcified Occlusive Disease

Get Shockwave IVL closer to occlusive calcium than ever before with Shockwave Javelin.* Its non-balloon-based design and single distal emitter enable you to modify and cross tight, challenging lesions, while minimizing complications like distal embolization.

Close-up image of the Shockwave Javelin Peripheral IVL catheter tip, including the single distal emitter and reinforced catheter shaft. Image includes illustrated sonic pressure waves to show how energy is delivered beyond the tip of the catheter

How Shockwave Javelin Works

  • Illustrated image demonstrating how the Shockwave Javelin Peripheral IVL Catheter is delivered to a calcified lesion within the vasculature, without the need for a balloon or inflation
  • Illustrated image demonstrating how gentle forward pressure is applied while the Shockwave Javelin Peripheral IVL Catheter generates sonic pressure waves to crack calcified lesions ahead of the catheter within the vasculature
  • Illustrated image demonstrating how the Shockwave Javelin Peripheral IVL Catheter advances through the vasculature and crosses a previously uncrossable calcified lesion
  • Illustrated image demonstrating how the Shockwave Javelin Peripheral IVL Catheter creates a lumen within the vasculature to enable therapy

Shockwave Javelin Peripheral Specifications

Illustrated image showing the details of the Shockwave Javelin Peripheral IVL catheter, including the emitter, IVL window, catheter connector and ports
Catalog Number Tip Entry Profile (in) Crossing Profile (in) Sheath Compatibility (Fr) Guidewire Compatibility Catheter Working Length (cm) Pulses/Cycle Cycles Pulses (Max)
JVNPIVLF 0.025 1.5 5 0.014 150 10 12 120

Forward PAD Investigational Device Exemption (IDE) Study

Shockwave Javelin safely and effectively modifies calcium to cross heavily calcified and severely stenosed above-the-knee (ATK) and below-the-knee (BTK) lesions.1

Safe & Effective for Crossing Heavily Calcified Lesions & Severely Stenosed Vessels

Statistics Callout

This section presents key statistical information with numbers and descriptions.

  • 93
    %
    Crossing success
  • 95
    %
    Moderate-to-severe calcification

Safe Calcium Treatment Option, Consistent with Commercially Available Balloon-Based IVL with Low Rates of Angiographic Complications & Major Adverse Events (MAE)

Statistics Callout

This section presents key statistical information with numbers and descriptions.

  • 1.2
    %
    Post-Shockwave Javelin angiographic complication rate
  • 4.1
    %
    Post-dilation angiographic complication rate
  • 1.0
    %
    Final angiographic complication rate
  • 1.1
    %
    MAE at 30 days

Effective Calcium Treatment Option, Consistent with Commercially Available Balloon-Based IVL with Similar Diameter Stenosis Reduction

Statistics Callout

This section presents key statistical information with numbers and descriptions.

  • 83
    %
    Pre-procedure diameter stenosis
  • 59
    %
    Post-Shockwave Javelin diameter stenosis
  • 31
    %
    Post-dilation diameter stenosis
  • 23
    %
    Final diameter stenosis
Shockwave Javelin Peripheral IVL Catheter: Device Overview & Case Review

Shockwave Javelin Device Overview & Case Review

In a brief video, Dr. JD Corl reviews his experience with Shockwave Javelin, the first-of-its-kind forward IVL platform designed to modify and cross calcified occlusive disease. Dr. Corl provides an overview of the new platform and three patient cases.


*Based on internal product specifications comparing existing Shockwave IVL devices.
**Internal testing shows a spherical sonic output from distal emitter consistent with previous Shockwave balloon-based IVL emitters, with sonic output extending beyond the tip of the catheter.
†Internal testing shows a spherical sonic output from distal emitter consistent with previous Shockwave balloon-based IVL emitters.

‡Dr. Corl is a paid consultant of Shockwave Medical.

1: Corl JD, Clair D, Mwipatayi P, et al. FORWARD PAD IDE/Feasibility Studies: Primary Endpoint Analysis of a Novel Non- Balloon-Based Peripheral IVL Catheter. JACC: Cardiovascular Interventions. Published online November 4, 2024. doi:10.1016/j.jcin.2024.10.035

2: Tepe, Gunnar et al. Intravascular Lithotripsy for Peripheral Artery Calcification: Mid-term Outcomes From the Randomized Disrupt PAD III Trial. Journal of the Society for Cardiovascular Angiography & Interventions, Volume 1, Issue 4, 100341. July-August, 2022.

3: Armstrong EJ, Adams G, Soukas PA, et al. Intravascular Lithotripsy for Peripheral Artery Calcification: 30-Day Outcomes From the Disrupt PAD III Observational Study. Journal of Endovascular Therapy. 2024;0(0). doi:10.1177/15266028241283716