Shockwave C2 Aero

You asked, Shockwave C2 Aero delivers. Our latest Coronary Intravascular Lithotripsy (IVL) catheter is engineered for improved deliverability and crossability, streamlining your calcium modification strategy.¹

Hero image of the Shockwave generator and Shockwave C2 Aero Intravascular Lithotripsy catheter
Hero image of the Shockwave generator and Shockwave C2 Aero Intravascular Lithotripsy catheter

Shockwave C2 Aero logo

An Aero-volution in Calcium Modification

Shockwave C2 Aero is more deliverable and easier to cross than previous generations of Shockwave coronary IVL. This isn’t just an upgrade – it’s an Aero-volution.

Illustrated graphic showing a close up of the Shockwave C2 Aero Intravascular Lithotripsy catheter, with individual parts/features labeled
Shockwave C2 Aero

Meet Shockwave C2 Aero

The latest addition to our IVL portfolio leverages our proven mechanism of action (MOA), delivering the same consistent circumferential ultrasonic pressure wave output to crack calcium safely and effectively.

Equidistant Emitter Placement

New catheter emitter configuration and tip design brings acoustic wave 3 mm closer to distal calcium.

  • The distal and proximal emitters were shifted 1 mm forward for equal distance between emitters and marker bands
  • The distal emitter is also 3 mm closer to the tip on Shockwave C2 Aero as compared to Shockwave C2+

Illustrated graphic showing a close up of the Shockwave C2+ and Shockwave C2 Aero Intravascular Lithotripsy catheters and their component measurements

 

Shockwave C2 Aero Specifications

Catalog Number Diameter Length Pulses Guidewire Compatibility Guide Catheter Compatibility Working Length Tip Profile Max Crossing Profile
C2AIVL2512 2.5 mm 12 mm 120 0.014 in 6 Fr 138 cm 0.022 in 0.044 in
C2AIVL3012 3.0 mm 12 mm 120 0.014 in 6 Fr 138 cm 0.022 in 0.045 in
C2AIVL3512 3.5 mm 12 mm 120 0.014 in 6 Fr 138 cm 0.022 in 0.045 in
C2AIVL4012 4.0 mm 12 mm 120 0.014 in 6 Fr 138 cm 0.022 in 0.047 in
Shockwave C2 Aero: Early Experience with Dr. Ahmad and Dr. Wanamaker

Shockwave C2 Aero: The Early Experience

Hear from Drs. Yousif Ahmad and Brett Wanamaker on their experience with Shockwave C2 Aero as they talk through the improved deliverability and crossability of the device, and how Shockwave C2 Aero is changing their treatment algorithm including case reviews.

1: Compared to Shockwave C2+ in simulated use bench testing. Based on feedback from physicians who participated in the Limited Market Release Survey.
2: Compared to Shockwave C2+ in simulated use bench testing.
3: Based on feedback from physicians who participated in the Limited Market Release Survey.
4: Designed with more tapered tip and new hydrophilic coating compared to Shockwave C2+.
5: Designed with more flexible material compared to Shockwave C2+.
6: Assuming one catheter is used in the procedure. Follow IFU.